Wind PV hybrid system for grid-independent
 energy supply:

 

  

Purpose: grid-independent energy supply for home appliances, TV, radios, radio stations, lighting, navigational, radio relay and weather stations. The system includes solar photoelectric and storage batteries, which insures supply of energy when wind speeds are below minimal.  The system have passed complete factory testing and certification.

 

 

 

Characteristics:

 

Parameters

Type I

Type II

Type III

Wind part:

Rated power, W

160

500

1000

Voltage, V

12

24

24

Type of current

Direct

Rotor diameter, m

1.6

2.5

3.3

Wind speeds, m/s

3.5-25

3.5-25

3-25

Weight, kg

52

60

250

Photovoltaic array Capacity, W:

 

60

 

120

 

180

Type of module

Number of modules

Weight, kg

FSM 36/4-Ñ

2

11

FSM 36/4-Ñ

4

22

FSM 36/4-Ñ

6

33

Invertor:

Rated power, W

Input Voltage, V

Output voltage, V

 

160

12

220  (50Hz)

 

500

24

220 (50Hz)

 

1000

24

220 (50 Hz)

Storage battery*

Amper-hour

100

200

460

 

* The storage battery does not enter into structure of delivery and is to be installed by the customer.

TO  HOME                    NEXT PAGE